sap data requirements
Latest entries from the Blog:
- BREEAM Very Good for development in London Borough of Southwark, SE5
- Energy Strategy for a 27 unit change of use in Lewisham
- Energy Strategy Statement for 59 dwellings in Slough
- 50 unit new housing project in Harwich
- BREEAM Very Good and supporting expertise in Ealing, W5
- Carbon Life Cycle Analysis for London Borough of Richmond-upon-Thames
- New building to meet code level 3 in Wandsworth
- Successful planning permission for Orangery in Buckingham
- Planning challenges in Kensington & Chelsea
- Planning permission for glazed extension in Tring
- Local Authority regulations met for new Conservatory in Aylesbury
- Dynamic Energy Assessors provide multiple SAP calculations for client near Redhill
Since SAP calculations are not based on a site survey submitting correct information is imperative for the production of valid SAP calculations and On Construction Energy Performance Certificates (OCEPC). The following are the suggested information sources and data items required.
information sources
Preferred are CAD “.dwg” drawings (paper copies or PDF files are also acceptable) of the following:
- Site plan to include orientation of the dwelling(s)
- Plans of each storey, normally at 1:50 scale
- Elevations drawings for each elevation
- Section drawing(s) representative of the dwelling
- Written specification describing the construction elements and services as per data items below
data items
Follow links to see details and examples
- Site Details
- Principal heating and hot water system
- Secondary heating system
- Ventilation
- Lighting
- Construction details
- Doors and Windows
- Renewable Technologies
Site Details
This will include everything that nationally identifies the dwelling, as a minimum it will include address & post code ^ Back to top
Primary heating system
Details to include make and model of boiler, details of heating emitters, hot water cylinder size (if applicable), system controls e.g: Worcester Greenstar Junior 24i; Radiators/underfloor heating; 140/190/250 litre hot water cylinder and Room thermostat + programmer + thermostatic radiator valves (TRV’s) ^ Back to top
Secondary heating system
Details of any secondary heating system present e.g. an electric fan heater, a gas fire room heater, an elctric radiant heater, a wood burning stove, etc. ^ Back to top
Ventilation Details
Details of all ventilation systems e.g. Xpelair extract fans to kitchen, bathroom, en-suite and utility ^ Back to top
Lighting Details
The details of all fixed internal and external lighting i.e. 25 low voltage (LV), 10 Low Energy (LE) and 2 modern strip lights and externally 2 LE floods ^ Back to top
Construction Details
For all different floors to the property to include: type & thicknesses of insulation and any other building products used e.g. 225mm thick hardcore / 1200g polythene / 125mm concrete slab / 50mm Celotex tuff-R Zero GA30000Z with 25mm perimeter insulation / 500g polythene separating layer / 65mm cement sand screed / 22mm composite laminate flooring
All different external walls to the property to include type and thicknesses of insulation and other building products used eg: 100mm facing brickwork / 50mm clear cavity / 100mm Celotex tuff-R CW3000Z partial fill cavity insulation / 100mm aggregate concrete block (BS EN 771-3) inner skin / 13mm 2-coat thistle plaster
All different roofs to the property to include type and thicknesses of insulation and other building products used eg: 100mm thick Rockwool Roll between ceiling joists cross laid with 170mm Rockwool Roll ^ Back to top
Details of Doors & Windows
Details of the doors and windows to include sizes, type of frame, type of glazing, thickness of glazing, and any low emissivity applications e.g: Argon filled, 4-16-4, UPVc windows, low E glazing soft coat. Manufacturer’s declared ‘U’ value = 1.6W/m2K ^ Back to top
Details of Renewable Technologies
Details of any renewable technologies installed e.g. Air Source Heat Pumps, Solar Water Heating, and Photovoltaic’s ^ Back to top